Folii nepermisive la vapori

AL90PI - 90g

  • Multi-layered metallised membranes reflect thermal radiation, providing additional heat loss prevention.
  • Such membranes can be used in all ventilated and non-ventilated roofs.
  • The membranes form an insulating barrier to vapour and wind.
  • Designed for habitable rooms in the attic. ADVANTAGES:
  • vapour-proof,
  • prevent heat losses by reflecting the thermal radiation,
  • additional wind and vapour barrier,
  • prevent the dampening of the thermal insulation of the roof,
  • tear-resistant thanks to reinforcement,
  • flexible and easy to install,

When used in combination with intermediate roof coating, the membranes ensure optimum ambient conditions in attic rooms.

Sd value m ≥150
Range of working temperatures °C -40
Surface weight g/m2 90
Weather resistance month 1
Standard reel length m 50
Fire class E
Standard reel width m 1,5
Thickness mm -
Range of working temperatures - from °C +80
Longitudinal tearing strength kN/m ≥210
Longitudinal tearing strength N/mm ≥300

AL150PI - 150g

  • Multi-layered metallised membranes reflect thermal radiation, providing additional heat loss prevention.
  • Such membranes can be used in all ventilated and non-ventilated roofs.
  • The membranes form an insulating barrier to vapour and wind.
  • Designed for habitable rooms in the attic. ADVANTAGES:
  • vapour-proof,
  • prevent heat losses by reflecting the thermal radiation,
  • additional wind and vapour barrier,
  • prevent the dampening of the thermal insulation of the roof,
  • tear-resistant thanks to reinforcement,
  • flexible and easy to install,

When used in combination with intermediate roof coating, the membranes ensure optimum ambient conditions in attic rooms.

Range of working temperatures °C -40
Weather resistance month 1
Surface weight g/m2 150
Sd value m ≥150
Standard reel length m 50
Fire class E
Standard reel width m 1,5
Thickness mm -
Range of working temperatures - from °C +80
Longitudinal tearing strength N/mm ≥300
Transverse tearing strength N/mm ≥210

ALME - 150g

BFAP and ALME are new-generation, non-woven polypropylene fabric-based vapour-proof membranes. The products are designed for vapour proofing of attics.

By ensuring vapour exchange, the product prevents moisture accumulation and condensation in the roof structure (between thermal insulation and plaster-cardboard panel).In addition, ALME is fitted with a reflective layer, which reflects thermal radiation, providing extra protection against heat loss. ADVANTAGES:

  • vapour-proof,
  • protects against potential condensation of the moisture accumulated in the roof/attic structure,
  • prevents the formation and development of fungi and moulds,
  • together with highly vapour-permeable STROTEX sarking membrane, the product forms an active roof system, which guarantees long life of the building,
  • slow-burning,
  • easy to install - handy format, light weight and overprints on the reel for easy and correct overlapping.
Surface weight g/m2 150
Thickness mm -
Sd value m ≥ 8
Longitudinal tearing strength N/mm ≥220
Transverse tearing strength N/mm ≥135
Weather resistance month 1
Fire class E
Range of working temperatures °C -40
Range of working temperatures - from °C +80
Standard reel width m 1,5
Standard reel length m 50

SLPI - 100g

Range of working temperatures °C -40
Weather resistance month 1
Surface weight g/m2 100
Sd value m ≥ 8
Standard reel length m 50
Fire class E
Standard reel width m 1,5
Thickness mm -
Range of working temperatures - from °C +80
Longitudinal tearing strength N/mm ≥750
Transverse tearing strength N/mm ≥750

110PI - 110g

Surface weight g/m2 110
Thickness mm -
Sd value m ≥ 8
Longitudinal tearing strength N/mm ≥300
Transverse tearing strength N/mm ≥250
Weather resistance month 1
Fire class E
Range of working temperatures °C -40
Range of working temperatures - from °C +80
Standard reel width m 1,5
Standard reel length m 50

140PI - 140g

Surface weight g/m2 140
Thickness mm -
Sd value m ≥ 8
Longitudinal tearing strength N/mm ≥300
Transverse tearing strength N/mm ≥250
Weather resistance month 1
Fire class E
Range of working temperatures °C -40
Range of working temperatures - from °C +80
Standard reel width m 1,5
Standard reel length m 50

BFAP - 100g

BFAP and ALME are new-generation, non-woven polypropylene fabric-based vapour-proof membranes. The products are designed for vapour proofing of attics.

By ensuring vapour exchange, the product prevents moisture accumulation and condensation in the roof structure (between thermal insulation and plaster-cardboard panel).In addition, ALME is fitted with a reflective layer, which reflects thermal radiation, providing extra protection against heat loss. ADVANTAGES:

  • vapour-proof,
  • protects against potential condensation of the moisture accumulated in the roof/attic structure,
  • prevents the formation and development of fungi and moulds,
  • together with highly vapour-permeable sarking membrane, the product forms an active roof system, which guarantees long life of the building,
  • slow-burning,
  • easy to install - handy format, light weight and overprints on the reel for easy and correct overlapping.
Sd value m ≥ 8
Transverse tearing strength N/5 cm ≥120
Standard reel length m 50
Standard reel width m 1,5
Range of working temperatures °C -40
Fire class E
Surface weight g/m2 100
Weather resistance month 1
Thickness mm -
Range of working temperatures - from °C +80
Longitudinal tearing strength N/mm ≥190
Transverse tearing strength N/mm ≥120

BFPI

BFPI membranes are excellent materials for vapour-proofing frame structures of walls, roofs and ceilings. Their mechanical strength is enhanced and their thickness is reduced thanks to multi-layer design. BFPI membrane is the only approved product of such type on the market. ADVANTAGES:

  • forms a tight roofing system when coupled with STROTEX sarking membrane and rockwool,
  • creates a tight floor system in combination with polyethylene floor mat.
Sd value m ≥150
Weather resistance month 1
Fire class E
Range of working temperatures °C -40
Standard reel length m 50
Surface weight g/m2 -
Standard reel width m 2; 2,7; 3
Thickness mm 0,15; 0,20
Range of working temperatures - from °C +80
Longitudinal tearing strength N/mm ≥125
Transverse tearing strength N/mm ≥95

EKPI

Weather resistance month 1
Fire class E
Range of working temperatures °C -40
Sd value m ≥150
Standard reel length m 50
Surface weight g/m2 -
Standard reel width m 2; 3
Thickness mm 0,15; 0,20
Range of working temperatures - from °C +80
Longitudinal tearing strength N/mm ≥80
Transverse tearing strength N/mm ≥70

FLPI

FLPI membranes are excellent materials for vapour-proofing frame structures of walls, roofs and ceilings. Their mechanical strength is enhanced and their thickness is reduced thanks to multi-layer design. FLPI membrane is the only approved product of such type on the market. ADVANTAGES:

  • forms a tight roofing system when coupled with sarking membrane and rockwool,
  • creates a tight floor system in combination with polyethylene floor mat.
Thickness mm 0,15; 0,20
Fire class E
Range of working temperatures °C -40
Standard reel width m 2; 3
Sd value m ≥150
Weather resistance month 1
Standard reel length m 50
Range of working temperatures - from °C +80
Longitudinal tearing strength N/mm ≥115
Transverse tearing strength N/mm ≥80

Banda ALtape - 150g

  • Multi-layered metallised membranes reflect thermal radiation, providing additional heat loss prevention.
  • Such membranes can be used in all ventilated and non-ventilated roofs. The membranes form an insulating barrier to vapour and wind. Designed for habitable rooms in the attic. ADVANTAGES:
  • vapour-proof,
  • prevent heat losses by reflecting the thermal radiation,
  • additional wind and vapour barrier,
  • prevent the dampening of the thermal insulation of the roof,
  • tear-resistant thanks to reinforcement,
  • flexible and easy to install,
  • by default, tape-type membrane is supplied with a glue strip for quick and problem-free joining of overlaps during installation on the roof.

When used in combination with intermediate roof coating, the membranes ensure optimum ambient conditions in attic rooms.

Surface weight g/m2 150
Thickness mm -
Sd value m ≥150
Longitudinal tearing strength N/mm ≥300
Transverse tearing strength N/mm ≥210
Weather resistance month 1
Fire class E
Range of working temperatures °C -40
Range of working temperatures - from °C +80
Standard reel width m 1,5
Standard reel length m 50