Folii nepermisive la vapori
AL90PI - 90g
- Multi-layered metallised membranes reflect thermal radiation, providing additional heat loss prevention.
- Such membranes can be used in all ventilated and non-ventilated roofs.
- The membranes form an insulating barrier to vapour and wind.
- Designed for habitable rooms in the attic. ADVANTAGES:
- vapour-proof,
- prevent heat losses by reflecting the thermal radiation,
- additional wind and vapour barrier,
- prevent the dampening of the thermal insulation of the roof,
- tear-resistant thanks to reinforcement,
- flexible and easy to install,
When used in combination with intermediate roof coating, the membranes ensure optimum ambient conditions in attic rooms.
Sd value | m | ≥150 |
Range of working temperatures | °C | -40 |
Surface weight | g/m2 | 90 |
Weather resistance | month | 1 |
Standard reel length | m | 50 |
Fire class | E | |
Standard reel width | m | 1,5 |
Thickness | mm | - |
Range of working temperatures - from | °C | +80 |
Longitudinal tearing strength | kN/m | ≥210 |
Longitudinal tearing strength | N/mm | ≥300 |
AL150PI - 150g
- Multi-layered metallised membranes reflect thermal radiation, providing additional heat loss prevention.
- Such membranes can be used in all ventilated and non-ventilated roofs.
- The membranes form an insulating barrier to vapour and wind.
- Designed for habitable rooms in the attic. ADVANTAGES:
- vapour-proof,
- prevent heat losses by reflecting the thermal radiation,
- additional wind and vapour barrier,
- prevent the dampening of the thermal insulation of the roof,
- tear-resistant thanks to reinforcement,
- flexible and easy to install,
When used in combination with intermediate roof coating, the membranes ensure optimum ambient conditions in attic rooms.
Range of working temperatures | °C | -40 |
Weather resistance | month | 1 |
Surface weight | g/m2 | 150 |
Sd value | m | ≥150 |
Standard reel length | m | 50 |
Fire class | E | |
Standard reel width | m | 1,5 |
Thickness | mm | - |
Range of working temperatures - from | °C | +80 |
Longitudinal tearing strength | N/mm | ≥300 |
Transverse tearing strength | N/mm | ≥210 |
ALME - 150g
BFAP and ALME are new-generation, non-woven polypropylene fabric-based vapour-proof membranes. The products are designed for vapour proofing of attics.
By ensuring vapour exchange, the product prevents moisture accumulation and condensation in the roof structure (between thermal insulation and plaster-cardboard panel).In addition, ALME is fitted with a reflective layer, which reflects thermal radiation, providing extra protection against heat loss. ADVANTAGES:
- vapour-proof,
- protects against potential condensation of the moisture accumulated in the roof/attic structure,
- prevents the formation and development of fungi and moulds,
- together with highly vapour-permeable STROTEX sarking membrane, the product forms an active roof system, which guarantees long life of the building,
- slow-burning,
- easy to install - handy format, light weight and overprints on the reel for easy and correct overlapping.
Surface weight | g/m2 | 150 |
Thickness | mm | - |
Sd value | m | ≥ 8 |
Longitudinal tearing strength | N/mm | ≥220 |
Transverse tearing strength | N/mm | ≥135 |
Weather resistance | month | 1 |
Fire class | E | |
Range of working temperatures | °C | -40 |
Range of working temperatures - from | °C | +80 |
Standard reel width | m | 1,5 |
Standard reel length | m | 50 |
SLPI - 100g
Range of working temperatures | °C | -40 |
Weather resistance | month | 1 |
Surface weight | g/m2 | 100 |
Sd value | m | ≥ 8 |
Standard reel length | m | 50 |
Fire class | E | |
Standard reel width | m | 1,5 |
Thickness | mm | - |
Range of working temperatures - from | °C | +80 |
Longitudinal tearing strength | N/mm | ≥750 |
Transverse tearing strength | N/mm | ≥750 |
110PI - 110g
Surface weight | g/m2 | 110 |
Thickness | mm | - |
Sd value | m | ≥ 8 |
Longitudinal tearing strength | N/mm | ≥300 |
Transverse tearing strength | N/mm | ≥250 |
Weather resistance | month | 1 |
Fire class | E | |
Range of working temperatures | °C | -40 |
Range of working temperatures - from | °C | +80 |
Standard reel width | m | 1,5 |
Standard reel length | m | 50 |
140PI - 140g
Surface weight | g/m2 | 140 |
Thickness | mm | - |
Sd value | m | ≥ 8 |
Longitudinal tearing strength | N/mm | ≥300 |
Transverse tearing strength | N/mm | ≥250 |
Weather resistance | month | 1 |
Fire class | E | |
Range of working temperatures | °C | -40 |
Range of working temperatures - from | °C | +80 |
Standard reel width | m | 1,5 |
Standard reel length | m | 50 |
BFAP - 100g
BFAP and ALME are new-generation, non-woven polypropylene fabric-based vapour-proof membranes. The products are designed for vapour proofing of attics.
By ensuring vapour exchange, the product prevents moisture accumulation and condensation in the roof structure (between thermal insulation and plaster-cardboard panel).In addition, ALME is fitted with a reflective layer, which reflects thermal radiation, providing extra protection against heat loss. ADVANTAGES:
- vapour-proof,
- protects against potential condensation of the moisture accumulated in the roof/attic structure,
- prevents the formation and development of fungi and moulds,
- together with highly vapour-permeable sarking membrane, the product forms an active roof system, which guarantees long life of the building,
- slow-burning,
- easy to install - handy format, light weight and overprints on the reel for easy and correct overlapping.
Sd value | m | ≥ 8 |
Transverse tearing strength | N/5 cm | ≥120 |
Standard reel length | m | 50 |
Standard reel width | m | 1,5 |
Range of working temperatures | °C | -40 |
Fire class | E | |
Surface weight | g/m2 | 100 |
Weather resistance | month | 1 |
Thickness | mm | - |
Range of working temperatures - from | °C | +80 |
Longitudinal tearing strength | N/mm | ≥190 |
Transverse tearing strength | N/mm | ≥120 |
BFPI
BFPI membranes are excellent materials for vapour-proofing frame structures of walls, roofs and ceilings. Their mechanical strength is enhanced and their thickness is reduced thanks to multi-layer design. BFPI membrane is the only approved product of such type on the market. ADVANTAGES:
- forms a tight roofing system when coupled with STROTEX sarking membrane and rockwool,
- creates a tight floor system in combination with polyethylene floor mat.
Sd value | m | ≥150 |
Weather resistance | month | 1 |
Fire class | E | |
Range of working temperatures | °C | -40 |
Standard reel length | m | 50 |
Surface weight | g/m2 | - |
Standard reel width | m | 2; 2,7; 3 |
Thickness | mm | 0,15; 0,20 |
Range of working temperatures - from | °C | +80 |
Longitudinal tearing strength | N/mm | ≥125 |
Transverse tearing strength | N/mm | ≥95 |
EKPI
Weather resistance | month | 1 |
Fire class | E | |
Range of working temperatures | °C | -40 |
Sd value | m | ≥150 |
Standard reel length | m | 50 |
Surface weight | g/m2 | - |
Standard reel width | m | 2; 3 |
Thickness | mm | 0,15; 0,20 |
Range of working temperatures - from | °C | +80 |
Longitudinal tearing strength | N/mm | ≥80 |
Transverse tearing strength | N/mm | ≥70 |
FLPI
FLPI membranes are excellent materials for vapour-proofing frame structures of walls, roofs and ceilings. Their mechanical strength is enhanced and their thickness is reduced thanks to multi-layer design. FLPI membrane is the only approved product of such type on the market. ADVANTAGES:
- forms a tight roofing system when coupled with sarking membrane and rockwool,
- creates a tight floor system in combination with polyethylene floor mat.
Thickness | mm | 0,15; 0,20 |
Fire class | E | |
Range of working temperatures | °C | -40 |
Standard reel width | m | 2; 3 |
Sd value | m | ≥150 |
Weather resistance | month | 1 |
Standard reel length | m | 50 |
Range of working temperatures - from | °C | +80 |
Longitudinal tearing strength | N/mm | ≥115 |
Transverse tearing strength | N/mm | ≥80 |
Banda ALtape - 150g
- Multi-layered metallised membranes reflect thermal radiation, providing additional heat loss prevention.
- Such membranes can be used in all ventilated and non-ventilated roofs. The membranes form an insulating barrier to vapour and wind. Designed for habitable rooms in the attic. ADVANTAGES:
- vapour-proof,
- prevent heat losses by reflecting the thermal radiation,
- additional wind and vapour barrier,
- prevent the dampening of the thermal insulation of the roof,
- tear-resistant thanks to reinforcement,
- flexible and easy to install,
- by default, tape-type membrane is supplied with a glue strip for quick and problem-free joining of overlaps during installation on the roof.
When used in combination with intermediate roof coating, the membranes ensure optimum ambient conditions in attic rooms.
Surface weight | g/m2 | 150 |
Thickness | mm | - |
Sd value | m | ≥150 |
Longitudinal tearing strength | N/mm | ≥300 |
Transverse tearing strength | N/mm | ≥210 |
Weather resistance | month | 1 |
Fire class | E | |
Range of working temperatures | °C | -40 |
Range of working temperatures - from | °C | +80 |
Standard reel width | m | 1,5 |
Standard reel length | m | 50 |
Pagina precedentă: Folii permisive la vapori